Application of single-phase motor in air compressor
1.Overview of Single-Phase Motor
Single-phase motor refers to an electric motor that runs on a single-phase AC power supply (usually 220V). It is one of the most commonly used power sources in air compressors, especially suitable for household and small industrial applications.
Basic features:
Power requirements: 220V single-phase AC
Power range: usually between 0.5HP (370W) and 5HP (3.7kW)
Starting method: capacitor start/capacitor operation, split-phase start, etc.
Speed: generally 2850rpm (2-pole) or 1450rpm (4-pole)
2.Requirements for single-phase motors in air compressors
High starting torque: need to overcome the high back pressure at the initial startup of the compressor
Frequent start-stop capability: the compressor is usually controlled by a pressure switch, and the motor needs to adapt to frequent start-stop
Thermal stability: long-term operation requires good heat dissipation design
Overload protection: built-in thermal protection device to prevent motor burnout
Low noise: especially sensitive to noise in the home environment
3.Typical applications of single-phase motors in air compressors
(1). Small household air compressors
Power: 0.5-2HP
Applications: air nail guns, tire inflation, small spraying, etc.
Features: portable design, noise controlled below 65dB
(2).Commercial air compressor
Power: 2-5HP
Application: Auto repair shop, small processing workshop
Features: Strong continuous working ability, large air tank capacity
(3).Special air compressor
Oil-free air compressor: adopts special sealing design, the motor needs to adapt to the oil-free environment
Silent air compressor: specially designed motor and soundproof cover
4.Selection guide
When selecting a single-phase motor for an air compressor, you should consider:
Power matching: the motor power should be 10-15% greater than the compressor shaft power
Starting characteristics: capacitor start/capacitor run (CSIR) type motor is preferred
Energy efficiency level: IE2 or higher energy efficiency level is preferred
Protection device: thermal protector must be built-in